Ground Water Level Sensor
Make : EnthuTech
Brand: ETS IoT
Model: ETS IoT-WL
Product Overview:
The ETS-WL is a LoRaWAN Ground Water Level Sensor used to measure the Water Level in the Borewell or Tanks. This measurement uses Hydrostatic Pressure sensing method for water level measurement. It uses LoRaWAN wireless technology to send the data to IoT Server. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption.
ETS IoT - WL supports BLE configure and wireless OTA update which
make user easy to use. It is powered by Solar panel + 3000mAh Li-Ion battery or 230VAC + 2600 mAh Li-Ion Battery or 8500mAh Li/SOCl2 Battery. The Image Shown above may vary based on the Power Source selection.
This has the option to connect upto 100 meter sensor cable to measure water level.
Salient Features:
o LoRaWAN 1.0.3 Class Ao ARM microcontroller with 256KB flash and 64KB RAM
o Ultra-low power consumption
o Measure water level based on pressure
o Different pressure range available
o Thread Installation Type or Immersion Type
o Monitor Battery Level
o Frequency Band: IN865
o Support Bluetooth v5.1 and LoRaWAN remote
configure
o Support wireless OTA update firmware
o Uplink on periodically
o Downlink to change configure
o IP67 Waterproof Enclosure
Accessories:
o Can be provided on request based on the Installationlocation
Applications:
o Water Level in Tanks, Borewell and WellPressure Sensor Specification:
o Hydrostatic Type, Probe IP Level: IP68o Measuring Range: Measure range can be customized,
up to 100m.
o Accuracy: 0.2% F.S
o Long-Term Stability: ±0.2% F.S / Year
o Storage temperature: -30℃~80℃
o Operating temperature: 0℃~50℃
o Material: 316 stainless steels
Power Supply Provisions (Optional to Select):
o 8500mAh Li/SOCl2 Non-Rechargeable Batteryo Solar panel + 3000mAh Li-Ion battery
o 230VAC Power + 2600mAh Li-Ion Battery
Operating Temperature Ratings:
o Operating Temperature: -40 ~ 85°CProduct Certification and Compliances:
o WPC, CE, IEC 61131-3:2013, IEC 61131-5:2013,ISO/IEC 14882:1998, ISO/IEC 17025:2017