Comparison

SPECIFICATION

YX 830

YX 1230

YX 1230 R

Heating zone quantity

8 Temperature Zones (Upper 4 Hot Air Heating Zones +Lower 4 Heating Zones)

12 Temperature Zone (Upper 6 Hot Air Heating Zones + Lower 6 Heating Zones)

12 Temperature Zone (Upper 6 Hot Air Heating Zones + Lower 6 Heating Zones)

Length of the heating zone

1400 X 300 mm

2080 x 300 mm

2052 x 390 mm

Heating type

Intelligent level sirocco and rapid infrared heating

Intelligent level sirocco and rapid infrared heating

Intelligent level sirocco and rapid infrared heating

Cooling zone quantity

2

2

2

Maximum width of PCB board

280 mm

280 mm

350 mm

Operation direction

Left → right

Left → right

Left → right

Delivery option

Net transmission chain transmission

Net transmission chain transmission

Net transmission chain transmission

Speed of conveyor belt

0 -- 2000 mm / min

0 -- 1500 mm / min

0 --1000 mm/min

Power supply

Three-phase 440 Volt AC / 50 Hz

Three-phase 440 Volt AC / 50 Hz

Three-phase 440 Volt AC /50 Hz

Starting power

11 kW

14 kW

39.55 kW

Operating Power

5 kW

5 kW

2.5 kW

Heating up time

Around 30 minutes

Around 30 minutes

15-25 minutes

Temperature control range

Room Temperature – 400

Room Temperature – 400

Room temperature -300

Temperature control mode

PID Closed-loop Control

PID Closed-loop Control

PID Closed-loop Control

Overall dimension

2500 x 710 x 1250 mm

3500 x 710 x 1250 mm

3894 x 960 x 1500 mm

Machine weight

240 Kg

400 Kg

850 Kg